Fluke 1507/1503 Insulation Testers

 

Features and benefits
• Insulation test range: 1507 - 0.01 M Ω to 10 G Ω; 1503 - 0.1 M Ω to 2000 M Ω
• Insulation test voltages: 1507 - 50 V, 100 V, 250 V, 500 V, 1000 V; 1503 - 500 V, 1000 V
• Save both time and money with Automatic calculation of Polarization Index and Dielectric Absorption Ratio
• Make repetitive tests simple and easy with the 1507’s Compare (Pass/Fail) function (only available on the 1507)  
• Repetitive or hard-to-reach testing is easy with the remote test probe
• Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
• Auto-discharge of capacitive voltage for added user protection
• AC/DC voltage: 0.1 V to 600 V
• 200 mA Continuity
• Resistance: 0.01 Ω to 20.00 K Ω
• Save battery power with auto power off
• Read measurements easily with large, backlit display
• CAT IV 600 V overvoltage category rating for added user protection
• Remote probe, test leads, probes and alligator clips included with each tester
• Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
• Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
• One-year warranty

1507/1503 Specifications

AC/DC voltage measurement

Range

Resolution

Accuracy

50 Hz to 400 Hz

 

± (% of Rdg + Digits)

600.0 V

0.1 V

± (2 % + 3)


Input impedance: 3 M Ω (nominal), < 100 pF
Common mode rejection ratio (1 kW unbalanced): > 60 dB at dc, 50 or 60 Hz
Overload protection: 600 V rms or dc

Earth bond resistance measurement

Range

Resolution

Accuracy

 

 

1 + (% of Rdg + Digits)

20.00 Ω

0.01 Ω

± (1.5 % + 3)

200.0 Ω

0.1 Ω

± (1.5 % + 3)

2000 Ω

1 Ω

± (1.5 % + 3)

20.00 k Ω

0.01 k Ω

± (1.5 % + 3)


1 Accuracies apply from 0 to 100 % of range.

Overload protection: 2 V rms or dc
Open circuit test voltage: > 4.0 V, < 8 V
Short circuit current: > 200.0 Ma

Accuracy (Model 1507)

Output Voltage

Display Range

Resolution

Test Current

Accuracy

 

 

 

 

± (% of Rdg + Digits)

50 V

0.01 M Ω to 20.00 M Ω

0.01 M Ω

1 mA @ 50 k Ω

± (3 % + 5)

(0 % to + 20 %)

20.0 M Ω to 50.0 M Ω

0.1 M Ω

1 mA @ 50 k Ω

± (3 % + 5)

100 V

0.01 M Ω to 20.00 M Ω

0.01 M Ω

1 mA @ 100 k Ω

± (3 % + 5)

(0 % to + 20 %)

20.0 M Ω to 100.0 M Ω

0.1 M Ω

1 mA @ 100 k Ω

± (3 % + 5)

250 V

0.01 M Ω to 20.00 M Ω

0.01 M Ω

1 mA @ 250 k Ω

± (1.5 % + 5)

(0 % to + 20 %)

20.0 M Ω to 200.0 M Ω

0.1 M Ω

1 mA @ 250 k Ω

± (1.5 % + 5)

500 V

0.01 M Ω to 20.00 M Ω

0.01 M Ω

1 mA @ 500 k Ω

± (1.5 % + 5)

(0 % to + 20 %)

20.0 M Ω to 200.0 M Ω; 200 M Ω to 500 M Ω

0.1 M Ω; 1 M Ω

1 mA @ 500 k Ω; 1 mA @ 500 k Ω

± (1.5 % + 5); ± (1.5 % + 5)

1000 V

0.1 M Ω to 200.0 M Ω

0.1 M Ω

1 mA @ 1 M

Ω  ± (1.5 % + 5)

(0 % to + 20 %)

200 M Ω to 2000 M Ω; 2.0 G Ω to 10.0 G Ω

1 M Ω; 0.1 G Ω

1 mA @ 1 M Ω; 1 mA @ 1 M Ω

± (1.5 % + 5); ± (10 % + 3)


Accuracy (Model 1503)

Output Voltage

Display Range

Resolution

Test Current

Accuracy

 

 

 

 

± (% of Rdg + Digits)

500 V

0.1 M Ω to 20.00 M Ω

0.01 M Ω

1 mA @ 500 k Ω

± (2.0 % + 5)

(0 % to + 20 %)

20.0 M Ω to 200.0 M Ω; 200 M Ω to 500 M Ω

0.1 M Ω; 1 M Ω

1 mA @ 500 k Ω; 1 mA @ 500 k Ω

± (2.0 % + 5); ± (2.0 % + 5

1000 V

0.1 M Ω to 200.0 M Ω

0.1 M Ω

1 mA @ 1 M Ω

± (2.0 % + 5)

(0 % to + 20 %)

200 M Ω to 2000 M Ω

1 M Ω

1 mA @ 1 M Ω

± (2.0 % + 5)


1507/1503 General Specifications
• Maximum voltage applied to any terminal: 600 V ac rms or dc
• Storage temperature:  -40 °C to 60 °C (-40 °F to 140 °F)
• Operating temperature: -20 °C to 55 °C (-4 °F to 131 °F)
• Temperature coefficient: 0.05 x (specified accuracy) per °C for temperatures < 18 °C or > 28 °C (< 64 °F or > 82 °F)
• Relative humidity noncondensing: 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F); 0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F); 0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F)
• Vibration: Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
• Shock: 1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)
• Electromagnetic compatibility: In an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)
• Safety: Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
• Certifications: CSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
• Batteries: Four AA batteries (NEDA 15A or IEC LR6)
• Insulation test use: Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MW with a duty cycle of 5 seconds on and 25 seconds off.
• Resistance measurements: Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 W with a duty cycle of 5 seconds on and 25 seconds off.
• Size: 5.0 cm H x 10.0 cm W x 20.3 cm L (1.97 in H x 3.94 in W x 8.00 in L)
• Weight: 550 g (1.2 lb)
• IP rating: IP40
• Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V
• Non-operating (storage): 12,000 m
• Over-range capability: 110 % of range

Included accessories
• TL224 Test Leads
• TP74 Test Probes
• Clips PN 1958654 (red) and PN 1958646 (black)
• Holster
• Remote probe